Yamaha MU10 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Stromgeneratoren Yamaha MU10 herunter. Yamaha MU10 Specification Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2 - PLEASE KEEP THIS MANUAL

9MIDIPOWERDC INTO HOSTOUT INON OFFHOST SELECTMIDI MacPC-2 PC-1A/D INPUTPanel Controls and Terminalst A/D INPUT jacks (1, 2)For connection of extern

Seite 3 - Welcome to the MU10

10The MU10 — What It Is and What It Can DoWhat It IsThe MU10 is a compact, highly portable MIDI tone generator, designedespecially for use with comput

Seite 4 - Unpacking

11The MU10 — What It Is and What It Can DoWhat It Can DoHere are a few application ideas on how you can use the MU10. The listbelow is not comprehens

Seite 5 - Table of Contents

12MIDIPOWERDC INTO HOSTOUT INON OFFHOST SELECTMIDI MacPC-2 PC-1Setting Up the MU10 in Your Music SystemWhatever your system, you should follow the b

Seite 6 - How to Use This Manual

13Setting Up Your MU10 Using BatteriesTo use the MU10 on battery power,remove the battery compartment cover(as shown at the right) and insert six1.5V

Seite 7 - Precautions

14Setting Up Your MU10ConnectionsIn this section you’ll learn how to set up your MU10 with a computer or withanother MIDI device. You’ll also learn h

Seite 8

15● MacintoshConnect the TO HOST terminalof the MU10 to the Modem (orPrinter) port of the computerwith an optional Apple Macin-tosh peripheral cable (

Seite 9

16MIDISetting Up Your MU10 Connecting to a Computer With a MIDI InterfaceConnect the MIDI IN terminal of theMU10 with the MIDI OUT terminalon the MID

Seite 10 - Panel Controls and Terminals

17Setting Up Your MU10Connecting to Audio EquipmentIn order to hear the sounds of the MU10, you must connect it to a set ofstereo headphones or an amp

Seite 11 - What It Is

18Using the A/D INPUT FunctionThe MU10 also features an A/D INPUT function that allows you to connect twoexternal audio sources — such as a microphone

Seite 12 - What It Can Do

This product utilizes batteries or an externalpower supply (adapter). DO NOT connect thisproduct to any power supply or adapter otherthan one describe

Seite 13 - Setting Up Your MU10

19Using the A/D INPUT Function● Operation1 Turn down all volume controls.This includes the A/D INPUTVOLUME sliders on the top panel,and the VOLUME sl

Seite 14 - ■ Using Batteries

20Using the A/D INPUT Function Changing the Input Gain SettingWhen the power is turned on, the A/D INPUTs are automatically set toreceive mic level s

Seite 15 - Connecting With a Computer

21MU10 Overview and FeaturesThis section covers the performance modes of theMU10 and describes in detail Voice- and Effect-related controls and featur

Seite 16

22MU10 Overview and Features Maximum PolyphonyThe MU10 can play a maximum of 32 notespolyphony at once. (When the A/D INPUT 1 jackor both the 1 and 2

Seite 17 - Connecting With a MIDI Device

23MU10 Overview and Features Effect TypesThe MU10 features dozens of extremely versatiledigital effects generated by Yamaha’s advancedDigital Signal

Seite 18 - Connecting to Audio Equipment

24 What is MIDI?MIDI is an acronym that stands for MusicalInstrument Digital Interface, which allowselectronic musical instruments to “communicate”wi

Seite 19 - Using the A/D INPUT Function

25101112131415161718191A1B1C281617181920212223242526271D29Dec Hex Dec Hex Dec Hex Dec Hex Dec Hex Dec Hex Dec Hex Dec Hex12345678910111213000102030405

Seite 20 - ● Operation

26You can select the Voice banks with MSB and LSBnumbers. MSB and LSB functions differentlydepending on the play mode.In XG mode, MSB numbers select V

Seite 21 - ● Operation

27MIDI Data Format1.2.13 Release TimeMessages which adjust the envelope release time setfor each Voice.CNTRL# PARAMETER DATA RANGE72 Release Time 0...

Seite 22 - MU10 Overview and Features

28MIDI Data FormatThe following NRPN numbers can be received.NRPNDATA ENTRYMSB LSB MSBPARAMETER NAME and VALUE RANGE01H 08H mmH Vibrato Ratemm : 00H-4

Seite 23

2Congratulations and thank you for purchasing the Yamaha MU10Tone Generator!Welcome to the MU10The MU10 is a sophisticated, yet highly compact MIDI to

Seite 24

29MIDI Data FormatHold1 0 (off)Portamento 0 (off)Sostenuto 0 (off)Soft Pedal 0 (off)Portamento Control cancels the Portamento SourceKey Number that wa

Seite 25 - About MIDI

30MIDI Data Format0ttttttt tt Volume MSB11110111 F7 End of Exclusiveor,11110000 F0 Exclusive status01111111 7F Universal Real Time0xxxnnnn xn Device N

Seite 26 - MIDI Data Format

31MIDI Data Format11110000 F0 Exclusive status01000011 43 YAMAHA ID0001nnnn 1n Device Number01001100 4C XG Model ID00000010 02 Address High00000001 01

Seite 27

32MIDI Data Format[ QS300 NATIVE ]1) QS300 User Normal Voice Data2.2.1 XG Native Bulk Dump11110000 F0 Exclusive status01000011 43 YAMAHA ID0000nnnn 0n

Seite 28

33MIDI Data Format MIDI Data Tables● Table 1-1Parameter Base AddressModel ID = 4C [XG]● Table 1-2MIDI Parameter Change Table ( SYSTEM ) [XG]Address S

Seite 29

34MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)02 01 20 2 00-7F CHORUS TYPE MSB Æ *1 41 (=CHORUS1)00-7F CHORUS T

Seite 30

35MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)02 01 70 1 00-7F VARIATIONPARAMETER 11 Æ *2 depends on variation

Seite 31

36MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)nn 30 1 00-01 Rcv PITCH BEND 0:OFF, 1:ON 01nn 31 1 00-01 Rcv CH A

Seite 32

37MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)nn 69 1 00-7F PITCH EG INITIAL LEVEL -64 - +63 40nn 6A 1 00-7F PI

Seite 33

38MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)00 48 1 NOT USED00 49 1 NOT USED00 4A 1 NOT USED00 4B 1 NOT USED0

Seite 34

3Your MU10 package should include the items listed below. Make sure thatyou have them all. Also, write down the serial number of your MU10 in thebox

Seite 35

39MIDI Data Format● Table 2-1Parameter Base AddressModel ID = 49 [MU10 ]● Table 2-2MIDI Parameter Change Table ( SYSTEM ) [ MU10 ]Address Size Data Pa

Seite 36

40MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)[Element 1]3D 00-7F Wave Number High bit 13 - bit 73E 00-7F Wave

Seite 37

41MIDI Data FormatAddress Size Data Parameter Description Default(H) (H) (H) value(H)80 00-0F Pan 0(Left)-14(Right),15:Scaling81 39-47 AEG Rate Scalin

Seite 38

42XG Normal Voice ListBank Select MSB=000, LSB=Bank NumberOrgan 17 0 DrawOrgn 132 DetDrwOr 233 60sDrOr1 234 60sDrOr2 235 70sDrOr1 236 DrawOrg2 237 60

Seite 39

43XG Normal Voice ListProgram#Ele-mentReed 65 0 SprnoSax 166 0 Alto Sax 140 Sax Sect 243 HyprAlto 267 0 TenorSax 140 BrthTnSx 241 SoftTenr 264 TnrSax

Seite 40

44TG300B Normal Voice ListBank Select MSB=Bank Number, LSB=000Program#Voice NameEle-mentProgram#Ele-mentOrgan 17 0 DrawOrgn 11 70sDrOr1 28 DetDrwOr 2

Seite 41

45TG300B Normal Voice ListProgram#Ele-mentBrass 57 0 Trumpet 11 Trumpet2 124 BriteTrp 225 WarmTrp 2126 Sax-3 1127 contrabs 158 0 Trombone 11 Trmbone2

Seite 42

46XG Drum Voice ListBank Select MSB=Bank Number, LSB=000Bank 127 127 127 127 127 127 127 127 127 126 126Program # 1 2 9 17 25 26 33 41 49 1 2Note# No

Seite 43 - XG Normal Voice List

47XG Drum Voice List60 C 3 Bongo H Burst Noise61 C# 3 Bongo L Coaster 62 D 3 Conga H Mute Analog Conga H SbMarine63 D# 3 Conga H Open Analog Conga M64

Seite 44

48Program # 1 9 17 25 26 33 41 49 57 128Note# Note Alternate Standard Kit Room Kit Power Kit Electro Kit Analog Kit Jazz Kit Brush Kit Orchestra Kit

Seite 45 - TG300B Normal Voice List

4Welcome to the MU10... 2Unpacking ...

Seite 46

49TG300B Drum Voice List73 C# 4 3 Guiro Short Machine Gun Vibraslap74 D 4 3 Guiro Long Laser Gun75 D# 4 Claves Analog Claves Explosion76 E 4 Wood Bloc

Seite 47 - XG Drum Voice List

50Effect Type ListREVERB00 00 NO EFFECT01 00 HALL101 01 HALL202 00 ROOM1 02 0

Seite 48

51Effect Parameter List 1 Reverb Time 0.3 ~ 30.0s 0-69 table#4 2 Diffusion 0 ~ 10 0-10 3 Initial Delay 0 ~ 63 0-63 table#5 4 HPF Cutoff T

Seite 49 - TG300B Drum Voice List

52Effect Parameter List• ● : Can be controlled by AC1 (Assignable Controller 1)• No. * : These numbers correspond to the Parameter Suffix numbers in&l

Seite 50

53Effect Parameter List• ● : Can be controlled by AC1 (Assignable Controller 1)• No. * : These numbers correspond to the Parameter Suffix numbers in&l

Seite 51 - Effect Type List

54Effect Data Assign TableData ValueLFO Frequency (Hz)Table#1Data Value Data Value0 0.001 0.042 0.083 0.134 0.175 0.216 0.257 0.298 0.349 0.3810 0.421

Seite 52 - Effect Parameter List

55SpecificationsTone Generation Method AWM2 (Advanced Wave Memory 2)Performance Modes XG mode, TG300B modeMaximum Simultaneous 32-note (last note prio

Seite 53

56TroubleshootingEven though the MU10 is exceptionally easy to use, it may occasionally not function asyou expect it to. If that happens, check the p

Seite 54

57Problem Possible Cause and SolutionNotes are cut off oromitted.The POWER lampflashes, even thoughMIDI messages are notbeing received.The maximum pol

Seite 55 - Effect Data Assign Table

58 YAMAHA [ Tone Generator ] Date:05-APR-1996 Model MU10 MIDI Implementation Chart Version : 1.0+------------------------

Seite 56 - Specifications

5You are probably eager to try out your new MU10 Tone Generator right away, ratherthan have to read through a lot of instructions before you can even

Seite 57 - Troubleshooting

59: 98-99 : x : o *1 :NRPN LSB,MSB :: 100-101 : x : o *1 :RPN LSB,MSB ::

Seite 58

For details of products, please contact your near-est Yamaha or the authorized distributor listedbelow.Pour plus de détails sur les produits, veuillez

Seite 59

SINGAPOREYamaha Music Asia Pte., Ltd.Blk 17A Toa Payoh #01-190 Lorong 7Singapore 1231Tel: 354-0133THAILANDSiam Music Yamaha Co., Ltd.865 Phornprapha B

Seite 60

FCC INFORMATION (U.S.A.)1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!This product, when installed as indicated in the instructions contained in this m

Seite 61 - NORTH AMERICA

2M.D.G., EMI Division © Yamaha Corporation 1996

Seite 62 - MIDDLE EAST

6PrecautionsYour MU10 will give you years of reliable service if you follow the simple rules givenbelow: LOCATIONDo not expose the instrument to the

Seite 63 - FCC INFORMATION (U.S.A.)

7Precautions TURN POWER OFF WHEN MAKING CONNECTIONSTo avoid damage to the instrument and other devices to which it is con-nected, turn the power swit

Seite 64

8MIN MAXVOLUME LINE OUT/PHONESPOWERA/D INPUTVOLUMETONE GENERATORGENERALPanel Controls and Terminalsq POWER lampLights when power is turned on. Also,

Kommentare zu diesen Handbüchern

Keine Kommentare