Ver. 3.1 2nd edition* This protocol document relates to the DME64N, DME24N, and DME Satellitewith DME firmware V1.2 or later.DME Remote Control Proto
15) RRSC: Used to relatively recall a scene.Option The DME's ACKs when it succeeds The DME's ACKs when it failsRRSC 0 [relative scene number
17) GSN: Used to obtain a scene name.Option The DME's ACKs when it succeeds The DME's ACKs when it failsGSN 0 [scene number] GSN OK GSN ERRS
To detect if an input level to the Audio Detector exceeds the threshold- The DME will return the one-line character string "GMT ERR" if it f
20) QCMT: Used to stop cyclical obtaining of a level meter.Option The DME's ACKs when it succeeds The DME's ACKs when it failsQCMT 0 [index]
Estimation of the cycle:Example 1: To obtain 1 ch level meter of 16ch Fader component,A required cycle for obtaining 1 level meter is 9 ms according t
3.3.5 GPI Control Command24) SGO: Used to control GPI OUT.Option The DME's ACKs when it succeeds The DME's ACKs when it failsSGO 0 [Port num
26) SWF: Used to stop playback of a file.Option The DME's ACKs when it succeeds The DME's ACKs when it failsSWF 0 SWF OK SWF ERRThe command
4. Command SequenceThe following are examples of the main command sequence.A parameter change (executed by Remote Controller)A parameter set commandDM
Registration to obtain level meter cycleDMESMC 0 500(setting the cycle for obtaining the meter to 500 msec)SMC OKGCMT 0 1 0(cyclically obtaining every
Troubleshooting (FAQ)Q:A:No, it is not possible. Be sure to set the baud rate of the remote controller to 38400bps. For more information, see the sect
1. Setup1.1 ConnectionTo control one DMETo control multiple DMEsTo debug the Remote Controller with a serial control application on a PC such as Hyper
AppendixA Fader Table of -∞ to 0 dBValue Data Value Data Value Data Value Data Value Data Value Data Value Data Value Data0 -InfdB 64 -87.50dB 128
Value Data Value Data Value Data Value Data Value Data Value Data Value Data Value Data512 -25.55dB 576 -22.35dB 640 -19.15dB 704 -15.95dB 768
A Fader Table of -∞ to 10 dBValue Data Value Data Value Data Value Data Value Data Value Data Value Data Value Data0 -InfdB 64 -71.80dB 128 -59.00
Value Data Value Data Value Data Value Data Value Data Value Data Value Data Value Data512 -15.55dB 576 -12.35dB 640 -9.15dB 704 -5.95dB 768
1.2 Remote Controller SettingThe Remote Controller settings for each connection are indicated as below.Settings for control via the REMOTE connectorB
1.4 DME Designer Settings* What is an index?An index is the row number in the Remote Control Setup List dialog. You will see each index number at the
2. Command ListCommands Notified to Remote Controller from the DMENo.1 PRM To notify a parameter change2 VOL To notify a parameter change3 SCN To noti
3. Command Specifications3.1 Basic Command SpecificationsA command type transmitted between the DME and the Remote Controller is in the following form
3.2.2 Scene Control Command3) SCN: Used when a scene is recalled.Command OptionSCN 0 [scene number]The command name stands for "Scene."The D
SVL OKVOL 0 6 323SVL ERR10) RSPR: Used to relatively set a parameter other than that for a fader, and a fader using a dB method.11) RSVL: Used to rel
- The first option will always take "0." It is reserved for future extensions to the command.- [index] will have an appropriate number conve