4 -5
4
Operation
4-5 Monitor function
■ Monitoring the I/O signals
The sequence I/O status can be monitored on the TPB.
[Display screen]
[MON-DIO]
DI 00000000 00000001
DO 11000000 O:1 S:1
* For information on how to display the monitor screen, refer to section 10-2, "DIO Moni-
tor Display", in the controller user's manual.
[Description]
DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
General-
purpose
input 7
General-
purpose
input 6
General-
purpose
input 5
General-
purpose
input 4
General-
purpose
input 3
General-
purpose
input 2
General-
purpose
input 1
General-
purpose
input 0
INH ORG-S RESET (NC) PCLR (NC) (NC) SERVO
Command
pulse inhibit
input
Return-to-
origin input
Alarm reset
input
(Empty)
Deviation
clear input
(Empty) (Empty)
Servo ON
input
ALM SRDY IN-POS DO4 DO3 DO2 DO1 DO0
Alarm output
Servo ready
output
In-position
output
General-
purpose
output 4
General-
purpose
output 3
General-
purpose
output 2
General-
purpose
output 1
General-
purpose
output 0
0
1 Servo ON
Servo OFF
0
1 ON (open)
OFF (close)
Column q (Input 1)
Column w (Input 2)
Column e (Output)
Column r
O: Origin sensor status
S: Servo status