MIDI Data Format
Many MIDI messages listed in the MIDI Data Format section are expressed in hexadecimal or
binary numbers. Hexadecimal numbers may include the letter “H” as a suffix. The letter “n”
indicates a certain whole number. The chart below lists the corresponding decimal number for
each hexadecimal/binary number.For more information, refer to the Owner’s Manual (page 118).
SYNTHESIZER/SEQUENCER PART
(1) TRANSMIT FLOW
MIDI<- +-[SW1]-+-------- NOTE ON/OFF 9nH
OUT | |
| |
| +-------- KEY'S AFTER TOUCH AnH (Seq only)
| |
| +-------- CONTROL CHANGE
| | MODULATION BnH,01H
| | VOLUME BnH,07H
| | PAN BnH,0AH
| | SUSTAIN SWITCH BnH,40H
| | FILTER RESONANCE BnH,47H
| | EG RELEASE TIME BnH,48H
| | EG ATTACK TIME BnH,49H
| | FILTER CUTOFF FREQ BnH,4AH
| | EG DECAY TIME BnH,4BH
| | REVERB SEND BnH,5BH
| | CHORUS SEND BnH,5DH
| | ASSIGNABLE CONTROLLERS BnH,(00H .. 5FH)
| | SEQ REMORT CONTROL BnH,(00H .. 7FH)
| |
| +-[SW7]-- BANK SEL MSB BnH,00H
| | BANK SEL LSB BnH,20H
| |
| +-------- CHANNEL MODE MESSAGE (Seq only)
| | RESET ALL CONTROLLERS BnH,79H
| | LOCAL CONTROL BnH,7AH
| | OMNI MODE OFF BnH,7CH
| | OMNI MODE ON BnH,7DH
| | MONO MODE ON BnH,7EH
| | POLY MODE ON BnH,7FH
| |
| +-[SW8]-- PROGRAM CHANGE CnH
| |
| +-------- CHANNEL AFTER TOUCH DnH
| |
| +-------- PITCH BEND CHANGE EnH
|
+-[SW4]---------- SYSTEM COMMON MESSAGE
| SONG POSITION POINTER F2H
|
+-[SW4]---------- SYSTEM REALTIME MESSAGE
| TIMING CLOCK F8H
| START FAH
| CONTINUE FBH
| STOP FCH
|
+---------------- ACTIVE SENSING FEH
|
+-[SW5]-+-------- SYSTEM EXCLUSIVE MESSAGE
| +-[SW6]-- <BULK DUMP>
F0H 43H 0nH 6BH bhH blH ahH amH alH ddH... ddH ccH F7H
| |
| +-[SW6]-- <PARAMETER CHANGE> F0H 43H 1nH 6BH ahH amH alH ddH.....ddH F7H
|
+---------------- SYSTEM EXCLUSIVE MESSAGE
IDENTITY REPLY F0H 7EH 7FH 06H 02H 43H 00H 41H 05H 2AH
00H 00H 00H 7FH F7H
[SW1] MIDI Transmit Channel
In the Master mode: complies with Zone Transmit Channel.
In the mode other than the Master: complies with Keyboard Transmit Channel.
[SW2] MIDI Control Mode
[SW4] Seq MIDI Control
[SW5] MIDI Device Number
When set to all, transmitted via 1.
[SW6] In the Voice mode, only the Voice related data can be transmitted.
In the Performance mode, only the Performance related data can be transmitted.
The System data can be transmitted/recognized in any mode.
[SW7] SYSTEM Bank Select Switch
[SW8] SYSTEM Program Change Switch
(2) RECEIVE FLOW
MIDI>- +[SW10]-+-------- NOTE OFF 8nH
| |
| +-------- NOTE ON/OFF 9nH
| |
| +-------- CONTROL CHANGE
| | MODULATION BnH,01H
| | PORTAMENTO TIME BnH,05H
| | DATA ENTRY MSB BnH,06H
| | DATA ENTRY LSB BnH,26H
| | MAIN VOLUME BnH,07H
| | PAN BnH,0AH
| | EXPRESSION BnH,0BH
| | SUSTAIN SWITCH BnH,40H
| | PORTAMENTO SWITCH BnH,41H
| | SOSTENUTO BnH,42H
| | HARMONIC CONTENT BnH,47H
| | EG RELEASE TIME BnH,48H
| | EG ATTACK TIME BnH,49H
| | BRIGHTNESS BnH,4AH
| | EG DECAY TIME BnH,4BH
| | EFFECT1 DEPTH BnH,5BH
| | EFFECT3 DEPTH BnH,5DH
| | DATA ENTRY INC BnH,60H
| | DATA ENTRY DEC BnH,61H
| | ALL SOUND OFF BnH,78H
| | ASSIGNABLE CONTROLLER BnH,(00H .. 5FH)
| | NRPN BnH,62H,63H *2
| | RPN
| | PITCH BEND SENS. BnH,64H,00H,65H,00H,06H,mmH
| | FINE TUNING BnH,64H,01H,65H,00H,06H,mmH,26H,llH *1
| | COARSE TUNING BnH,64H,02H,65H,00H,06H,mmH *1
| | RPN RESET BnH,64H,7FH,65H,7FH
| |
| +-[SW2]-- EG SUSTAIN LEVEL BnH,1FH
| |
| +-[SW7]-- BANK SEL MSB BnH,00H
| | BANK SEL LSB BnH,20H
| |
| +-------- CHANNEL MODE MESSAGE
| | RESET ALL CONTROLLERS BnH,79H
| | OMNI MODE OFF BnH,7CH
| | OMNI MODE ON BnH,7DH
| | MONO MODE ON BnH,7EH
| | POLY MODE ON BnH,7FH
| +-[SW8]-- PROGRAM CHANGE CnH
| |
| +-------- CHANNEL AFTER TOUCH DnH
| |
| +-------- PITCH BEND CHANGE EnH
|
+-[SW3]-+-------- SYSTEM REALTIME MESSAGE
| TIMING CLOCK F8H
|
+-[SW4]-+-------- SYSTEM REALTIME MESSAGE
| START FAH
| CONTINUE FBH
| STOP FCH
|
+---------------- ACTIVE SENSING FEH
|
+-[SW5]-+-------- SYSTEM EXCLUSIVE MESSAGE
| | MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
| |
| +-[SW9]-- <BULK DUMP>
F0H 43H 0nH 6BH bhH blH ahH amH alH ddH....ddH ccH F7H *3
| |
| +-[SW6]-- <PARAMETER CHANGE>
F0H 43H 1nH 6BH ahH amH alH ddH.....ddH F7H *3
| |
| +-[SW6]-- <BULK DUMP REQUEST>
F0H 43H 2nH 6BH ahH amH alH ddH.....ddH F7H *3
| |
| +-[SW6]-- <PARAMETER REQUEST> F0H 43H 3nH 6BH ahH amH alH F7H *3
| |
| +-[SW11]- XG SYSTEM ON F0H 43H 1nH 4CH 00H 00H 7EH 00H F7H
| |
| +-[SW11]- GM MODE ON F0H 7EH 7FH 09H 01H F7H
|
+---------------- SYSTEM EXCLUSIVE MESSAGE
IDENTITY REQUEST F0H 7EH 0nH 06H 01H F7H
[SW2] MIDI Control Mode
[SW3] MIDI Sync (can be set to "internal", or "MIDI")
[SW4] Seq MIDI Control
[SW5] MIDI Device Number
When this is not set to off, the MIDI Master Volume can be recognized in any mode.
[SW6] In the Voice mode, only the Voice related data can be transmitted.
In the Performance mode, only the Performance related data can be transmitted.
The System data can be transmitted/recognized in any mode.
[SW7] SYSTEM Bank Select Switch
[SW8] SYSTEM Program Change Switch (In the Voice mode, recognized only in the play mode.)
[SW9] SYSTEM Bulk Protect and same as SW6.
[SW10] MIDI Receive Channel
In the Mixing mode: complies with Part Receive Channel and Part Receive Switch.
In the other mode: complies with Basic Receive Channel.
[SW11] SYSTEM Receive GM/XG On